城市公园防雷技术规范
Technical specifications for lightning protection in urban parks
发 布 湖南省市场监督管理局2021-05发布-07 2021-08实施-0743
DB43/T2065—2021 湖南省地方标准
ICS
CCS
07.060
A 47
DB43/T 2065—2021
I
目 次
前言 ································ ································ ································ ························ Ⅲ
1 范围 ································ ································ ································ ····················· 1
2 规范性引用文件 ································ ································ ································ ······ 1
3 术语和定义 ································ ································ ································ ············ 1
4 一般规定 ································ ································ ································ ··············· 3
5 雷电防护措施 ································ ································ ································ ········· 3
6 防雷装置的检测与维护 ································ ································ ····························· 4
附录A(资料性) 冲击电流值 ································ ································ ······················ 5
参考文献 ································ ································ ································ ···················· 6
DB43/T 2065—2021
II
DB43/T 2065—2021
III
前 言
本文件按照 GB/T 1.1 —2020《标准化工作导则 第1部分:标准化文件的结构和起草规则》的规
定起草。
请注意本文件的某些内容可能涉及专利。本文件的发布机构不承担识别专利的责任。
本文件由湖南省气象局提出。
本文件由湖南省气象标准化技术委员会 归口。
本文件起草单位:邵阳市气象局
本文件主要起草人:罗龙友、邹德培、李福勇、周晖、王佩、黎亮、唐红民、肖林兵、舒慧、王道
平、薛德锋、秦向宏、陈代亮 。
DB43/T 2065—2021
IV
DB43/T 2065—2021
1
城市公园防雷技术规范
1 范围
本文件规定了城市公园设施的防雷措施与要求。
本文件适用于城市公园设施的防雷设计、施工及日常维护。
2 规范性引用文件
下列文件中的内容通过文中的规范性引用而构成本文件必不可少的条款。 其中, 注日期的引用文件,
仅该日期对应的版本适用于本文件;不注日期的引用文件,其最新版本(包括所有的修改单)适用于本
文件。
GB 50057 —2010 建筑物防雷设计规范
GB 50343 —2012 建筑物电子信息系统防雷技术规范
GB 51017 —2014 古建筑防雷工程技术规范
GB 50601 —2010 建筑物防雷工程施工与质量验收规范
GB/T 28102 —2011 城市公共休闲服务与管理导则
GB/T 21431 —2015 建筑物防雷装置检测技术规范
QX/T 231 —2014 古树名木防雷技术规范
3 术语和定义
下列术语和定义适用于本文件。
3.1
城市公园 city park
供公众游 览、观赏、休憩、开展科学、文化及休闲等活动,有较为完善的设施及良好的绿化环境、
景观优美的公共绿地。包括综合性公园、儿童公园、文物古迹公园、纪念性公园、风景名胜公园、动物
园、带状公园等。
[GB/T 38584 —2020,定义3]
3.2
游乐设施 amusement devices
游乐设施是指在特定的区域内运行 ,承载游客游乐的载体。包括具有动力的游乐器械﹐为游乐而设
置的构筑物和其他附属装置以及无动力的游乐载体。
[QX/T 264 —2015,定义3.6]
3.3
避雷亭 lightning pav ilion
公园内供游客观景、休息﹑躲雨和避雷的亭式建 (构)筑物。
[QX/T 264 —2015,定义3.8]
DB43/T 2065—2021
2 3.4
古树 ancient tree
树龄在100年以上的树木。
[QX/T 231 —2014,定义3.1]
3.5
名木 rare tree
珍贵稀有或具有历史、科学、文化价值以及有重要纪念意义的树木。
[QX/T 231 —2014,定义3.2]
3.6
防雷装置 lightning protection system
用于减少闪击击于建 (构)筑物上或建 (构)筑物附近造成的物质性 损害和人身伤亡 ,由外部防雷装置
和内部防雷装置组成。
[GB 50057 —2010,定义2.0.5]
3.7
外部防雷装置 external lightning protection system
由接闪器、引下线和接地装置组成。
[GB 50057 —2010,定义2.0.6]
3.8
接闪器 air-termination system
由拦截闪击的接闪杆、接闪带 ,接闪线、接闪网以及金属屋面、金属构件等组成。
[GB 50057 —2010,定义2.0.8]
3.9
引下线 down -conduc tor system
用于将雷电流从接闪器传导至接地装置的导体。
[GB 50057 —2010,定义2.0.9]
3.10
接地体 earth electrode
埋人土壤中或混凝土基础中作散流用的导体。
[GB 50057 —2010,定义2.0.11]
3.11
电气系统 electrical system
由低压供电组合部件构成的系统。也称低压配电系统或低压配电线路。
[GB 50057 —2010,定义2.0.26]
3.12
电子系统 electronic system
由敏感电子组合部件 构成的系统。
[GB 50057 —2010,定义2.0.27]
3.13
标称放电电流 nominal discharge current
流过浪涌保护器,具有 8/20us波形的电流峰值,用于浪涌保护器的Ⅱ类试验以及Ⅰ类、Ⅱ类试验
的预处理试验。
[GB 50343 —2012,定义2.0.19]
DB43/T 2065—2021
3
4 一般规定
4.1 城市公园的雷电灾害防御 ,应在调查地理、地质、土壤、气象、环境等条件和雷电活动规律、城市
公园特点等基础上,确定防护措施并按照 GB 50057 —2010 中6.2.1的规定进行防雷区的划分。
4.2 城市公园游憩设施 (非建筑类 )、游憩设施 (建筑类)、观景平台、电气和电子系统、游乐园 (场)水
景设施、古树名木及其他空旷地带等易发生雷电灾害的场所 ,在新改扩过程中,应在雷电灾害风险评估
的基础上 ,采取综合防雷措施。
4.3 景观照明设施应按下列要求进行防雷类别划分
4.3.1 固定在建 (构)筑物上的景观照明设施 ,应按照建 (构)筑物的防雷类别进行确定。
4.3.2 当景观照明设施不属于上述情况时 ,应参照第三类防雷类别进行确定。
5 雷电防护措施
5.1 外部防雷措施
5.1.1 城市公园游客服务中心、管理办公用房、变电配电所等独立的建 (构)筑物,直击雷防护应按 GB
50057—2010要求采取直击雷防护措施。
5.1.2 城市公园中历史名园具有文化价值的古建 (构)筑物应按照 GB 51017—2014采取直击雷防护措
施,古树名木的防雷应符合